VACUUM BELT FILTER
  1. Filtrating area :2-144 m2
  2. Vacuum consumption : 8-360 m3/min
Share This Product:
  • BRIGHT SPOT OF PRODUCT
  • MAIN PARAMETER PRODUCT
  • MORE

 Equipment Introduction

The Horizontal Vacuum Belt Filter use filtering fabric as the filter medium, which utilizes the material gravity and vacuum suction to realize the separation of the solid and liquid.


 Operating Principle

This equipment adopts the fixed vacuum chamber, the rubber belt is drived by the gearbox and running continuously on the vacuum chamber, the cloth moving synchronously on the rubber belt. The friction belt on the slipway of vacuum chamber forming a water sealing structure with rubber belt. The slurry feeding on the cloth smoothly and evenly by feeding hopper. When the vacuum chamber connects with vacuum system, the filtering area with vacuum suction will be formed on the rubber belt, the filtrate pass through the cloth and flow to the grooves and holes of rubber belt to vacuum chamber, the solids formed a cake on the surface of cloth. The filtrate in the vacuum chamber discharged by the vacuum tank. Moving by the rubber belt, the cake moving to the cake washing area and drying area sequentially, then enter into cake discharging area. After discharging cake, the cloth washed by washing system and enter into next filtering cycle.


 Features

● Modular design, flexible assembly and convenient transportation are implemented for structure. Also, can deliver the whole assembled equipment after installation and commissioning.

● The filter cloth and rubber belt operating synchronously is applied to the filter, which can be finished the process of continuous feeding, filtering, washing, drying and cloth washing.

● The remote control and local control can be exchanged to achieve unmanned operations.

● On the rubber belt support, we can use rollers, air cushion, pallet and multiple friction belts to reduce the friction resistance and prolong the rubber belt life time.

● Use filtrate or clean water for the cake washing, and collect the filtrate by sections.

● Use high pressure water for cloth washing to increase the cloth regenerative effect and the life span.

● Filtrate discharge types include automatic discharge, high level discharge and auxiliary discharge.

● Gas cover or aluminum plastic Windows can be designed partial closed or totally enclosed for partial insulation or the centralized collection for the volatile gas or steam of slurry.


SPECIFICATION PARAMETERS
filtration   width  mm filtration area m² filtration  length m weight    T Dimension (L×W×H)mm
500 2 4 3.0 7820×2000×2000
2.5 5 3.2 8820×2000×2000
3 6 3.4 9900×2000×2000
5 10 3.8 14000×2200×2000
800 4.8 6 5.0 10050×2500×2000
6.4 8 5.5 12050×2500×2000
8 10 6.0 14100×2600×2000
9.6 12 7.0 16250×2600×2000
1000 5 5 5.3 8870×2600×2000
6 6 5.8 10500×2600×2000
8 8 6.3 12500×2800×2000
10 10 6.8 14500×2800×2000
12 12 7.3 16500×2800×2000
14 14 7.8 18500×2800×2000
1300 7.8 6 7.2 10400×3150×2000
10.4 8 8.3 12400×3150×2000
13 10 9 14400×3150×2000
15.6 12 10.5 16400×3150×2000
18.2 14 11.5 18400×3150×2000
20.8 16 12.5 20400×3150×2000
1800 14.4 8 12.7 12600×4000×2200
18 10 13.7 14600×4000×2200
21.6 12 15.3 16600×4000×2200
25.2 14 16.6 18600×4000×2200
28.8 16 17.9 20600×4000×2200
2000 16 8 14.2 12700×4200×2200
20 10 15.4 14700×4200×2200
24 12 17.2 16700×4200×2200
28 14 18.7 18700×4200×2200
32 16 20.2 20700×4200×2200
36 18 21.7 22700×4200×2200
2500 25 10 22 14500×4800×2200
30 12 25.3 16500×4800×2200
35 14 27.4 18500×4800×2200
40 16 29.5 21500×4800×2400
45 18 31.6 23500×4800×2400
50 20 38.6 25600×4800×2400
2800 33.6 12 20.5 17600×5000×2500
39.2 14 24.1 19600×5000×2500
3000 36 12 22 17600×5500×2800
42 14 24 19600×5500×2800
48 16 28 21600×5500×2800
54 18 30.6 23600×5500×2800
60 20 35.2 25600×5500×2800
3200 44.8 14 35.3 19500×5700×3100
48 15 36.2 20500×5700×3100
51.2 16 37.7 21500×5700×3100
57.6 18 40.1 23500×5700×3100
64 20 42.5 25500×5700×3100
72 22.5 52.4 28500×5700×3100
4000 72 18 56.2 24000×7100×3300
80 20 58.8 26000×7100×3300
88 22 66.6 28000×7100×3300
96 24 69.4 30000×7100×3300
104 26 72.2 32000×7100×3300
4500 90 20 72 26500×7500×3600
99 22 75.2 28500×7500×3600
108 24 78.4 30500×7500×3600
117 26 81.6 32500×7500×3600
126 28 84.8 34500×7500×3600
135 30 88 36500×7500×3600
144 32 93 38500×7500×3600
Feedback from contact with us
Related Product
DOUBLE ROLLER DEWATERING MACHINE DJY100
DOUBLE ROLLER DEWATERING MACHINE DJY100
Capacity:15 m³/h Motor power(kw): 3 kw Dimension(LxWxH)(mm): 1600×1300×1300 ...
More >
SPF STACKED FILTER PRESS SPFⅠ, SPFⅡ, SPFⅢ, SPFⅣ
SPF STACKED FILTER PRESS SPFⅠ, SPFⅡ, SPFⅢ, SPFⅣ
Filter Area/m2:1-3 Plate Qty/layer: 2-6 Hydraulic Station Power/KW: 7.5 ...
More >
CERAMIC DISC FILTER CF-1,CF-15,CF-80,CF-144
CERAMIC DISC FILTER CF-1,CF-15,CF-80,CF-144
Plate Qty:12-240pcs Filtrating area/m2 : 1-144 Operating power : 2-89KW ...
More >
Product Catalog